  • Code: E880-0005
  • Description: HDD cooling fan (FM21) error. When detect a failure of the power supply cooling fan
  • Remedy: 1. Connector disconnection 2. HDD cooling fan (FM21) failure
  • Code: E881-0001
  • Description: CPU abnormal temperature rising error. It was detected that CPU was 100 deg C or more.
  • Remedy: When it is detected that the temperature of the CPU is 100 deg C or more, forcible shutdown is executed. After that, the error is recorded in the error log. • If the error occurred during a service visit and then occurred again: Replace the Main Controller PCB 1. • If the error does not occur during a service visit but is found in the log: 1. Check the space behind the host machine. If the space behind the host machine is less than 10 cm, ask the user to secure enough space. 2. Clean the inlet on the rear of the host machine. Remove dust.
  • Code: E905-0001
  • Description: POD deck light air assist fan error. Even when the maximum LOW interval was passed, there was no change in the signal.
  • Remedy: 1. Failure of the shutter 2. Failure of the swing sensor (PS11) 3. Failure of the swing motor (M3) 4. Failure of the deck controller PCB (UN1)
  • Code: E905-0002
  • Description: POD deck pickup motor cooling fan error. The pickup motor cooling fan is not placed at LOCK ON status.
  • Remedy: 1. Check the connector of the pickup motor cooling fan (FM4). 2. Replace the pickup motor cooling fan. 3. Replace the deck controller PCB.
  • Code: E905-0003
  • Description: POD deck pickup motor cooling fan error. The pickup motor cooling fan is not placed at LOCK OFF status.
  • Remedy: 1. Check the connector of the pickup motor cooling fan (FM4). 2. Replace the pickup motor cooling fan. 3. Replace the deck controller PCB.
  • Code: E906-0001
  • Description: POD deck light air heater high temperature error. A temperature over 120 degreeC was detected for 1 second consecutively.
  • Remedy: 1. Failure of the environment sensor (SR1) 2. Failure of the warm air fan (FAN1) 3. Failure of the cool air fan (FAN2) 4. Failure of the additional fan (FAN3) 5. Failure of the air heater (H1) 6. Failure of the deck controller PCB (UN1)
  • Code: E906-0002
  • Description: POD deck light air heater low temperature error. The heater is not placed in the Ready status even when a specified period of time has elapsed.
  • Remedy: 1. Failure of the environment sensor (SR1) 2. Failure of the warm air fan (FAN1) 3. Failure of the cool air fan (FAN2) 4. Failure of the additional fan (FAN3) 5. Failure of the air heater (H1) 6. Failure of the deck controller PCB (UN1)
  • Code: E991-0000
  • Description: Backup RAM error. SRAM in the DCON detected data error.
  • Remedy: Replace the DCON PCB