Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR2800 — Trang 15/15

Code: E805-0003

Description: The clock signal is absent for 5 sec or more after the fan drive signal has been generated. The detail codes of the fans in question are as follows:
curl reducing fan (FM4)
Causes: The fan wiring is faulty (short circuit, open circuit). The fan is faulty. The DC controller PCB is faulty.
Remedy: 1. Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter. 2. Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection. 3. Fan, DC controller PCB Try replacing the fan. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.

Code: E805-0004

Description: The clock signal is absent for 5 sec or more after the fan drive signal has been generated. The detail codes of the fans in question are as follows:
curl reducing fan (FM5)
Causes: The fan wiring is faulty (short circuit, open circuit). The fan is faulty. The DC controller PCB is faulty.
Remedy: 1. Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter. 2. Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection. 3. Fan, DC controller PCB Try replacing the fan. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.

Code: E805-0005

Description: The clock signal is absent for 5 sec or more after the fan drive signal has been generated. The detail codes of the fans in question are as follows:
electrical unit fan (FM3)
Causes: The fan wiring is faulty (short circuit, open circuit). The fan is faulty. The DC controller PCB is faulty.
Remedy: 1. Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter. 2. Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection. 3. Fan, DC controller PCB Try replacing the fan. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.

Code: E901-0000

Description: The motor ready signal does not arrive within 1.3 sec after the pedestal main motor drive signal is generated
Causes: The connector has poor connector. The pedestal main motor is faulty. The main power supply PCB is faulty. The pedestal controller PCB is faulty. The DC controller PCB is faulty.
Remedy: 1. Connector Is the wiring between the pedestal controller PCB and the main power supply PCB and between the main power supply PCB and the DC controller PCB normal? NO: Correct the wiring. 2. Main power supply PCB Is the voltage between J206-2 (+) and J206-1 (-) on the main power supply PCB about 24 V? NO: Replace the main power supply PCB. 3. Pedestal main motor Try replacing the pedestal main motor. Is the problem corrected? YES: End. 4. Pedestal controller PCB, DC controller PCB Try replacing the pedestal controller PCB. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.