Description: There is an error in the communication with the finisher.
The communication with the finisher does not resume within 5 sec after it has been disrupted.
Remedy: Check the cable. Replace the DC controller PCB. Replace the finisher controller PCB.
Code: E716-0000
Description: There is an error in the communication with the pedestal.
After the presence of a pedestal has been detected, the communication fails to be normal for 5 sec
Remedy: Check the cable. Replace the DC controller PCB. Replace the pedestal drive PCB.
Code: E717-0001
Description: There is an error in the communication with the NE controller.
The NE controller is not connected at power on, although it was connected before the power was turned off because of an error.
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Code: E717-0002
Description: There is an error in the communication with the NE controller.
An IPC error has occurred while the NE controller is in operation. There is an open circuit for the IPC. An error has occurred, and the IPC communication remains disabled
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Code: E719-0001
Description: There is a coin vendor error.
The coin vendor is not connected when the power is turned on, although it was connected before the power was turned off because of an error.
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Code: E719-0002
Description: There is a coin vendor error.
While the coin vendor is in operation, an IPC error has occurred, IPC has developed an open circuit, or an error preventing recovery of IPC communication has occurred. An open circuit has been detected in the line for the pickup/delivery signal. An illegal signal has been detected.
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Code: E719-0003
Description: There is a coin vendor error.
While the unit price is being checked at startup, an error occurs in the communication with the coin vendor.
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.
Code: E719-0011
Description: There is a coin vendor error.
An error has occurred at new card reader startup. The new card reader is not connected when the power is turned off, although it was connected when the power was turned off.
Remedy: Check the cable; thereafter, reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR.