Các lỗi thường gặp

Code :
  • Code: E000-0001
  • Description: The temperature of the fixing assembly is abnormally high.
    While startup control is under way, the reading of the main thermistor is less than 30 deg C continuously for 200 msec or more 1 sec after the start of power supply. While startup control is under way, the reading of the main thermistor is less than 70 deg C continuously for 200 msec or more 2 sec after the start of power supply. While startup control is under way, the reading of the main thermistor is less than 120 deg C continuously for 200 msec 6 sec after the start of power supply. The startup control does not end 30 sec after the start of power supply.
  • Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the main thermistor. Replace the DC controller PCB.
  • Code: E001-0000
  • Description: The temperature of the fixing assembly is abnormally high.
    The reading of the main thermistor is 250 deg C or more continuously for 200 msec.
  • Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the main thermistor. Replace the DC controller PCB.
  • Code: E001-0001
  • Description: The temperature of the fixing assembly is abnormally high.
    The hardware circuit detects overheating of the main or sub thermistor for 200 msec.
  • Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the DC controller PCB.
  • Code: E001-0002
  • Description: The temperature of the fixing assembly is abnormally high.
    The reading of the sub thermistor is 295 deg C or more continuously for 200 msec.
  • Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the sub thermistor. Replace the DC controller PCB.
  • Code: E002-0000
  • Description: The rise in temperature of the fixing assembly is faulty
    While startup control is under way, the reading of the main thermistor is less than 115 deg C continuously for 400 msec 1.3 sec after it has indicated 100 deg C. While startup control is under way, the reading of the main thermistor is less than 150 deg C continuously for 400 msec 1.3 sec after it has indicated 140 deg C.
  • Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the main thermistor. Replace the DC controller PCB.
  • Code: E003-0000
  • Description: The fixing temperature is too low after a standby state.
    While regular temperature control is under way, the reading of the main thermistor is less than 140 deg C continuously for 400 msec or more.
  • Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the main thermistor. Replace the DC controller PCB.
  • Code: E007-0000
  • Description: The rotation of the fixing film is faulty.
    While the fixing motor is rotating, the marker signal is not detected for 6 sec with the reading of the main thermistor indicating 100 deg C or more.
  • Remedy: Reset the condition in service mode: COPIER>FUNCTION>CLEAR> ERR. Replace the main thermistor. Replace the DC controller PCB.
  • Code: E010-0001
  • Description: The rotation of the main motor is faulty.
    Detection is executed every 100 msec after the start of motor rotation; however, the drive detection signal is absent for 2 sec.
  • Remedy: Replace the main motor. Replace the DC controller PCB.