Các lỗi thường gặp

Code :
  • Code: E315-0010
  • Description: Abnormality of image data
    ASIC (for compression/decompression) on the image conversion PCB is faulty. Timeout error during decoding
  • Remedy: Check on connection of the image conversion board, Replace the image conversion board
  • Code: E315-0025
  • Description: Abnormality of image data
    ASIC (for compression/decompression) on the image conversion PCB is faulty. Image data transfer error during rotation processing.
  • Remedy: Check on connection of the image conversion board, Replace the image conversion board
  • Code: E315-0028
  • Description: Abnormality of image data
    ASIC (for compression/decompression) on the image conversion PCB is faulty. Timeout error during rotation processing
  • Remedy: Check on connection of the image conversion board, Replace the image conversion board
  • Code: E315-0034
  • Description: Abnormality of image data
    ASIC (for scaling processing) on the image conversion PCB is faulty. Image data transfer error during scaling processing
  • Remedy: Check on connection of the image conversion board, Replace the image conversion board
  • Code: E315-0036
  • Description: Abnormality of image data
    ASIC (for scaling processing) on the image conversion PCB is faulty. Timeout error during scaling processing
  • Remedy: Check on connection of the image conversion board, Replace the image conversion board
  • Code: E351-0000
  • Description: Main controller PCB error
    Communication error of the main controller PCB occurs at start-up.
  • Remedy: Check on connection between the main controller PCB and the main controller PCB (sub) , Replace the main controller PCB, Replace the main controller PCB (sub)
  • Code: E400-0001
  • Description: Feeder communication error
    Checksum error
  • Remedy: Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)
  • Code: E400-0002
  • Description: Feeder communication error
    Reception status error
  • Remedy: Check on connection between the ADF controller PCB and the main controller PCB (sub), Replace the ADF controller PCB, Replace the main controller PCB (sub)