Các lỗi thường gặp

Code :
  • Code: E315-0551
  • Description: There is an error in image data.
    Device: abnormal termination error [Location to be detected] image process module (PRIP) [Detection timing] when abnormal interruption is detected after the operation has been started.
  • Remedy: Check connection with DDI-P cable(DCON). Replace the main controller PCB.
  • Code: E315-0560
  • Description: There is an error in image data.
    Device: timeout error [Location to be detected] image process module (PRIO) [Detection timing] when there is no interruption 2 min after the operation has been started.
  • Remedy: Check connection with DDI-P cable(DCON). Replace the main controller PCB.
  • Code: E315-0561
  • Description: There is an error in image data.
    Device: abnormal termination error [Location to be detected] image process module (PRIO) [Detection timing] when abnormal interruption is detected after the operation has been started.
  • Remedy: Check connection with DDI-P cable(DCON). Replace the main controller PCB.
  • Code: E400-0001
  • Description: Fault in communication with the ADF driver PCB
    The checksum values of data from the ADF driver PCB are inconsistent 14 times consecutively.
  • Remedy: Check connection of ADF lattice cable (cleaning of connecting point). Replace ADF driver PCB. Replace the reader controller PCB.
  • Code: E400-0002
  • Description: The statuses of data from the ADF driver PCB are inconsistent 14 times consecutively.
  • Remedy: Check connection of ADF lattice cable (cleaning of connecting point). Replace ADF driver PCB. Replace the reader controller PCB.
  • Code: E400-0003
  • Description: SCI serial communication error interrupt is detected 14 times consecutively.
  • Remedy: Check connection of ADF lattice cable (cleaning of connecting point). Replace ADF driver PCB. Replace the reader controller PCB.
  • Code: E413-0001
  • Description: The level of the pressure HP sensor does not change in a specified period of time.
    When the pressure motor is activated, the level of the pressure HP sensor does not change in a specified period of time with the lead roller opened.
  • Remedy: Replace the pressure motor. Replace the pressure HP sensor.
  • Code: E413-0002
  • Description: The level of the pressure HP sensor does not change in a specified period of time.
    When the pressure motor is activated, the level of the pressure HP sensor does not change in a specified period of time with the lead roller closed.
  • Remedy: Replace the pressure motor. Replace the pressure HP sensor.