Mã lỗi Canon iR3225 — Trang 6/30
Description: EEPROM error
An error has occurred during read operation following write operation.
Remedy: Replace the reader controller PCB
Description: The zero-cross signal is faulty.
When the relay is on, the zero-cross signal is not detected for 500 msec or more.
Remedy: Replace the AC driver PCB. Replace the DC controller PCB.
Description: Reading unit communication error
Reception status error
Remedy: Disconnect and then connect the flexible cable. Replace the flexible cable
Description: Reading unit communication error
Reception interrupt error
Remedy: Disconnect and then connect the flexible cable. Replace the flexible cable
Description: Reading unit communication error
Insufficient insertion of the reading unit connector
Remedy: Disconnect and then connect the flexible cable. Replace the flexible cable
Description: There is an error in image data.
There is an error in JBIG encoding.
Remedy: Turn off and then back on the power.
Description: There is an error in image data.
There is an error in JBIG decoding.
Remedy: Turn off and then back on the power.
Description: There is an error in image data.
Error in decoding of software
Remedy: Replace the main controller PCB