Thương hiệu phân phối chính hãng
Giỏ hàng

Mã lỗi Canon iR3320 — Trang 14/15

Code: E740-0002

Description: The MAC address has a fault
Causes: The LAN card is faulty. The main controller PCB is faulty.
Remedy: 1. Connector Is the connection between the LAN card and the main controller PCB normal? NO: Correct the connection. 2. LAN card, Main controller PCB Try replacing the LAN card. Is the problem corrected? YES: End. NO: Replace the main controller PCB.

Code: E740-0003

Description: The LAN card cannot be read
Causes: The LAN card is faulty. The main controller PCB is faulty.
Remedy: 1. Connector Is the connection between the LAN card and the main controller PCB normal? NO: Correct the connection. 2. LAN card, Main controller PCB Try replacing the LAN card. Is the problem corrected? YES: End. NO: Replace the main controller PCB.

Code: E741-0000

Description: The PCI bus has a fault
Causes: The PCI bus has poor connection. The main controller PCB is faulty.
Remedy: Each PCI slot may be disabled in service mode to prevent the error: BOARD>PCI1-OFF through PCI3-OFF. 1. Board Is the connection between the relay board and the main controller PCB normal? NO: Correct the connection. 2. Relay board, Main Controller PCB Try replacing the relay board. Is the problem corrected? YES: End. NO: Replace the main controller PCB.

Code: E743-0000

Description: The reader controller PCB detects a fault in the communication between the main controller PCB and the reader controller PCB
Causes: The connector has poor connection. The main controller PCB has a fault.
Remedy: 1. Connector, Main controller PCB Is the connection between the connector J1014 on the main controller PCB and the connector J409 on the reader controller PCB normal? NO: Correct the connection. YES: Replace the main controller PCB.

Code: E744-0000

Description: The BootROM on the main controller PCB and the system software are for different models or are of different types
Causes: The BootROM is not mounted correctly, or a fault occurred during downloading or when downloading the system software.
Remedy: Downloading (system software) Check the types of the BootROM and the system software, and download system software of the correct type.

Code: E803-0000

Description: The 24V output from the composite main power supply PCB is absent for 1 sec or more
Causes: The wiring is faulty (short circuit, open circuit). The composite power supply PCB is faulty. The DC controller PCB is faulty.
Remedy: 1. Connectors Are the connectors J204 on the main power supply PCB and the connector J300 on the DC controller PCB connected securely? NO: Connect the connectors securely. 2. Main power supply PCB Is 24 V supplied by the main power supply PCB (J204) to the DC controller PCB (J300)? (J204-5 <-> J300-5: OVU3, J204-6 <-> J300-6: OVU3, J204-7 <-> J300-7: 24VU3, J204-8 <-> J300-8: 24VU3) NO: Replace the main power supply PCB. YES: Replace the DC controller PCB.

Code: E805-0001

Description: The clock signal is absent for 5 sec or more after the fan drive signal has been generated. The detail codes of the fans in question are as follows:
developing fan (FM1)
Causes: The fan wiring is faulty (short circuit, open circuit). The fan is faulty. The DC controller PCB is faulty.
Remedy: 1. Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter. 2. Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection. 3. Fan, DC controller PCB Try replacing the fan. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.

Code: E805-0002

Description: The clock signal is absent for 5 sec or more after the fan drive signal has been generated. The detail codes of the fans in question are as follows:
fixing fan (FM2)
Causes: The fan wiring is faulty (short circuit, open circuit). The fan is faulty. The DC controller PCB is faulty.
Remedy: 1. Foreign matter Is there foreign matter that prevents the rotation of the fan? YES: Remove the foreign matter. 2. Wiring, Connector Are the wiring and connector of the fan normal? Developing fan (FM1): DC controller PCB (J302B) Fixing fan (FM2): DC controller PCB (J308B) Curl reducing fan (FM4): DC controller PCB (J311B) Curl reducing fan (FM5): DC controller PCB (J311B) Electrical unit fan (FM3): main controller PCB (J1028) NO: Correct the wiring and the connection. 3. Fan, DC controller PCB Try replacing the fan. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.
Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin Đăng ký nhận bản tin
Đăng ký nhận bản tin
Nhận ưu đãi sớm nhất khi chương trình diễn ra

Đăng ký nhận bản tin

Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này. Chính sách cookie