Description: After the main motor drive signal is generated, the clock signal does to arrive within 1.3 sec
Causes: The main motor (M2) is faulty. the DC controller PCB is faulty.
Remedy: 1. Connector Is the connector of the main motor connected? NO: Connect the connector. 2. Main power supply PCB Is the drive voltage (24 V) of the main motor supplied by the main power supply PCB? Main power supply PCB: between J202-1 (24VU1-SW) and J202-2 (OVU1) NO: Replace the main power supply PCB. 3. Main controller (M2), DC controller PCB Press the Start key. Is the lock signal of the main motor present at the connector J308 on the DC controller PCB? Lock signal: J318-A10 (MM_LOCK) YES: Replace the main motor. NO: Check the wiring; if normal, replace the DC controller PCB.
Code: E014-000
Description: After the fixing motor drive signal is generated, the clock signal does not arrive within 1.3 sec
Causes: The fixing motor (M19) is faulty. The DC controller PCB is faulty.
Remedy: 1. Connector Is the connector of the fixing motor connected? NO: Connect the connector. 2. Main power supply PCB Is the drive voltage (24 V) of the fixing motor supplied by the main power supply PCB? Main power supply PCB: between J202-3 (24VU1-S) and J202-4 (OVU1) NO: Replace the main power supply PCB. 3. Fixing motor (M19), DC controller PCB Press the Start key. Is the lock signal of the fixing motor present at the connector (J312) on the DC controller PCB? Lock signal: J312-B4 (FSRM_LOCK*) the DC controller PCB change from 0 to about 5 V? YES: Replace the fixing motor. NO: Replace the DC controller PCB.
Code: E019-0000
Description: The waste toner case is full of waste toner
Causes: The waste toner case is full. The waste toner case full detection mechanism is soiled. The waste toner sensor is faulty. The DC controller PCB is faulty. Caution To clear the error, dispose of the waste toner, and turn off and then on the main power switch.
Remedy: 1. Waste toner case full detection mechanism Remove the waste toner case, and turn off and then on the main power switch. Is 'E019' absent? YES: The waste toner case full detection assembly is soiled with toner. Clean both inside and outside of area A of the waste toner case with alcohol. Make sure that no dirt remains inside and outside the area around the round recess. 2. Waste toner full sensor, DC Controller PCB Try replacing the waste toner case full sensor. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.
Code: E032-0001
Description: The DA unit connection is disconnected (after connection).
Causes: The DA unit is faulty. The main controller PCB is faulty.
Remedy: 1. Connector Is the DA unit connected securely? NO: Connect it securely. 2. DA controller, Main controller PCB Try replacing the DA unit. Is the problem corrected? YES: End. NO: Replace the main controller PCB.
Code: E051-0000
Description: At start-up, home position is not detected when the horizontal registration assembly is moved 100 mm in the direction of home position
Causes: The horizontal home position sensor is faulty. The horizontal registration motor is faulty. The DC controller PCB is faulty.
Remedy: 1. Connector Are the connectors of the horizontal registration home position sensor and the horizontal registration motor connected? a. DC controller PCB (J304) <-> relay connector <-> horizontal registration home position sensor b. DC controller PCB (J304) <-> relay connector <-> horizontal registration motor NO: Connect the connectors. 2. Sensor lever (damage and interference), Sensor Is abnormal noise heard from the horizontal registration assembly in keeping with the motor rotation? YES: a. The horizontal registration assembly is out of place because of damage to the sensor lever. Replace the sensor lever. b. The horizontal registration assembly malfunctions because of the presence of foreign matter. Remove the foreign matter. c. The sensor is faulty and cannot detect home position. Replace the sensor. 3. Horizontal registration motor, DC controller PCB Is the horizontal registration motor control signal generated by the DC controller PCB? J304-1/2: 24 V, J304-3/4/5/6: motor excitation signal YES: The horizontal registration motor is faulty. Replace the motor. NO: Replace the DC controller PCB.
Code: E064-0000
Description: The presence of a high-voltage error is communicated by the composite power supply PCB (The output for primary charging, developing, or transfer has deviated from a specific level of voltage)
Causes: The contact has poor connection. The wiring is faulty. The composite power supply PCB is faulty. The DC controller PCB is faulty. proce
Remedy: 1. Contact Is any of the contacts of the primary charging roller, developing assembly, or transfer charging roller soiled? Or, is there poor contact? YES: Clean the contact, and set it once again. 2. Wiring Is the wiring between the contacts for the following normal: DC controller PCB (J301), composite power supply PCB (J136), primary charging roller, developing assembly, transfer charging roller? a. DC controller PCB (J301) <-> composite power supply PCB (J136) b. composite power supply PCB (J130-7) <-> primary charging roller contact c. composite power supply PCB (J130-1) <-> developing assembly contact d. composite power supply PCB (FT133) <-> transfer roller contact NO: Correct the connection. 3. Composite power supply PCB, DC controller PCB Try replacing the composite power supply PCB. Is the problem corrected? YES: Yes. NO: Replace the DC controller PCB.
Code: E100-0001
Description: The BD signal is not detected 10 times or more within 10 msec in 5 msec after the generation of the laser drive signal
Causes: The wiring is faulty (short circuit, open circuit). The BD PCB is faulty. The laser scanner unit is faulty. The DC controller PCB is faulty.
Remedy: 1. BD PCB Try replacing the BD PCB. Is the problem corrected? YES: End. 2. Laser scanner unit, DC controller PCB Try replacing the laser scanner unit. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.
Code: E100-0001
Description: The BD signal is not detected 10 times or more within 10 msec in 5 msec after the generation of the laser drive signal
Causes: The wiring is faulty (short circuit, open circuit). The BD PCB is faulty. The laser scanner unit is faulty. The DC controller PCB is faulty.
Remedy: 1. BD PCB Try replacing the BD PCB. Is the problem corrected? YES: End. 2. Laser scanner unit, DC controller PCB Try replacing the laser scanner unit. Is the problem corrected? YES: End. NO: Replace the DC controller PCB.