Các lỗi thường gặp

Code :
  • Code: E713-0000
  • Description: There is a sorter IPC error.
    An error has been detected in the sorter communication IC.
  • Remedy: - Check the connection of the cable. - Replace the finisher controller PCB. - Replace the DC controller PCB.
  • Code: E717-0001
  • Description: There is a fault in the communication with the NE controller. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    An error has occurred at time of NE controller start-up. The NE controller that was connected before power-off is not connected at power-on.
  • Remedy: - Check the connection of the cable.
  • Code: E717-0002
  • Description: There is a fault in the communication with the NE controller. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    There is an IP error while the NE controller is in operation. The IPC may have an open circuit or the IPC communication cannot be recovered.
  • Remedy: - Check the connection of the cable.
  • Code: E719-0001
  • Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    An error has occurred at time of coin vendor start-up. The coin vendor was connected before power-off, but is not connected at power-on.
  • Remedy: - Check the connector of the cable.
  • Code: E719-0002
  • Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    An IPC error has occurred while the coin vendor is in operation. The IPC may have an open circuit, or the IPC communication cannot be recovered. The pickup/delivery signal line has an open circuit. An illegal connection has been detected.
  • Remedy: - Check the connector of the cable.
  • Code: E719-0003
  • Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    While a unit price is being obtained at start-up, an error has occurred in the communication with the coin vendor.
  • Remedy: - Check the connector of the cable.
  • Code: E719-0011
  • Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    An error has occurred at card reader start-up. The card reader that was connected before power-off is not connected at power-on.
  • Remedy: - Check the connector of the cable.
  • Code: E719-0012
  • Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
    An IPC error has occurred while the card reader is in operation. The IPC may have an open circuit, or the IPC communication cannot be recovered.
  • Remedy: - Check the connector of the cable.