Description: Error in controller board.
Error in detection of the controller plate differs from the equipment
Remedy: - Replace the main controller PCB.
Code: E804-0000
Description: There is a DC power supply fan error/there is an IH power supply cooling fan error.
The DC power supply fan stop signal has been detected for 5 sec or more even when the DC power fan is on.
Remedy: - Check the connection of the connector. - Replace the fan.
Code: E804-0001
Description: There is a DC power supply fan error/there is an IH power supply cooling fan error.
The IH power supply cooling fan stop signal has been detected for 5 sec or more even when the IH power supply cooling fan is on.
Remedy: - Check the connection of the connector. - Replace the fan.
Code: E804-0002
Description: There is a DC power supply fan error/there is an IH power supply cooling fan error.
The accessories power supply cooling fan stop signal has been detected for 5 sec or more even when the accessories power supply cooling fan is on.
Remedy: - Check the connection of the connector. - Replace the fan.
Code: E805-0001
Description: There is a heat discharge fan error/there is a feed fan error.
The heat discharge fan stop signal has been detected for 5 sec or more even when the heat discharge fan is on.
Remedy: - Check the connection of the connector. - Replace the fan.
Code: E805-0002
Description: There is a heat discharge fan error/there is a feed fan error.
The feed fan stop signal has been detected for 5 sec even when the feed fan is on.
Remedy: - Check the connection of the connector. - Replace the fan.
Code: E808-0001
Description: IH power supply input error
The IH power supply input voltages are higher than the stipulated voltages
Remedy: - Connect with the outlet of a correct voltage. - Check the connection of the connector. - Replace the fixing heater power supply.
Code: E808-0002
Description: IH power supply input error
The IH power supply input voltages are lower than the stipulated voltages
Remedy: - Connect with the outlet of a correct voltage. - Check the connection of the connector. - Replace the fixing heater power supply.