Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then back on without resetting the error
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E003-0000
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The reading of the main thermistor is lower than 70 deg C for 2 sec or more after it has exceeded 100 deg C.
Remedy: connection and wiring. - Check the main/shutter thermistor for mounting condition. - Replace the main/shutter thermistor. - Replace the fixing heater unit. - Replace the DC controller PCB.
Code: E003-0010
Description: There is an abnormal rise in temperature. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then back on without resetting the error.
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E004-0010
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The power has been turned off and then back on without resetting the error.
Remedy: - Reset the error. (COPIER>FUNCTION>CLEAR>ERR)
Code: E004-0101
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
There is a mismatch between the input voltage and the IH power supply ID.
Remedy: Replace the fixing heater power supply with one designed for the country of installation (voltage).
Code: E004-0102
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The IH current is faulty. (current leakage)
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Code: E004-0103
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
The IH current is faulty. (no current)
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.
Code: E004-0104
Description: The IH power supply is faulty/the IH control mechanism is faulty. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
There is an IH over-current.PCB.
Remedy: - Check the connector for any fault in connection. - Replace the fixing heater power supply. - Replace the DC controller PCB.