Description: There is a sorter IPC error.
An error has been detected in the sorter communication IC.
Remedy: - Check the connection of the cable. - Replace the finisher controller PCB. - Replace the DC controller PCB.
Code: E717-0001
Description: There is a fault in the communication with the NE controller. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
An error has occurred at time of NE controller start-up. The NE controller that was connected before power-off is not connected at power-on.
Remedy: - Check the connection of the cable.
Code: E717-0002
Description: There is a fault in the communication with the NE controller. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
There is an IP error while the NE controller is in operation. The IPC may have an open circuit or the IPC communication cannot be recovered.
Remedy: - Check the connection of the cable.
Code: E719-0001
Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
An error has occurred at time of coin vendor start-up. The coin vendor was connected before power-off, but is not connected at power-on.
Remedy: - Check the connector of the cable.
Code: E719-0002
Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
An IPC error has occurred while the coin vendor is in operation. The IPC may have an open circuit, or the IPC communication cannot be recovered. The pickup/delivery signal line has an open circuit. An illegal connection has been detected.
Remedy: - Check the connector of the cable.
Code: E719-0003
Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
While a unit price is being obtained at start-up, an error has occurred in the communication with the coin vendor.
Remedy: - Check the connector of the cable.
Code: E719-0011
Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
An error has occurred at card reader start-up. The card reader that was connected before power-off is not connected at power-on.
Remedy: - Check the connector of the cable.
Code: E719-0012
Description: There is a fault in the coin vendor. After correcting the fault, be sure to reset the error. (COPIER>FUNCTION>CLEAR>ERR)
An IPC error has occurred while the card reader is in operation. The IPC may have an open circuit, or the IPC communication cannot be recovered.