Code: E204-0000

Description: There is an error in the detection of the image leading edge signal.
During forward movement in fixed reading mode or during a home position search, the image leading signal does not occur; or, in stream reading mode, the image leading edge signal does not arrive from the ADF controller PCB.
Remedy: Caution No code will be indicated. The keys will be locked. You can check the code in service mode (COPIER>DISPLAY>ERR). - Check if the scanner motor is connected properly, and replace the scanner motor if necessary. - Replace the scanner image leading edge sensor. - Replace the reader controller PCB.

Code: E211-0000

Description: The rise in temperature of the scanning lamp heater is faulty.
While the power is ON, the ambient temperature of the scanning lamp does not exceed 10 deg C 2 min after the florescent heater has gone ON; or, after the power is turned on, the reading of the ambient temperature of the scanning lamp is 0 deg C or lower.
Remedy: - Check if the connecter (J852, J853) of the light control PCB is mounted properly. - Replace the scanning lamp heater. - Replace the light control PCB. - Replace the reader controller PCB.

Code: E215-0000

Description: The rise in temperature of the scanning lamp heater is faulty.
While the scanning lamp is OFF, the reading of the ambient temperature is 170 deg C or higher.
Remedy: - Check if the connecter (J852, J853) of the light control PCB is mounted properly. - Replace the scanning lamp heater. - Replace the light control PCB. - Replace the reader controller PCB.

Code: E218-0000

Description: The scanning lamp is not mounted properly.
When the power is turned on, the absence of the scanning lamp is detected.
Remedy: - Check if the scannning lamp is mounted properly. - Check if the connecter (J1002, J1003) of the inverter PCB is mounted properly. - Check if the connector (J1720) of the relay PCB is mounted properly. - Replace the scanning lamp. - Replace the reader controller PCB.

Code: E219-0000

Description: The scanning lamp life
While the scanning lamp is ON, the reading of the ambient temperature is 170 deg C or higher.
Remedy: - Check if the connecter (J852, J853) of the light control PCB is mounted properly. - Replace the scanning lamp heater. - Replace the light control PCB. - Replace the reader controller PCB.

Code: E220-0000

Description: The lighting of the scanning lamp is faulty.
The scanning lamp does not reach a specific intensity within 10 sec after it is tuned on (if the room temperature is 10 deg C or lower, within 60 sec). Or, the ON detection signal (FL-DTCT) does not go OFF within 5 sec after the scanning lamp is turned off; during shading adjustment, the ON detection signal (FL-DTCT) does not go ON within 60 sec after the scanning lamp is turned on.
Remedy: - Check if the connecter (J852, J853) of the light control PCB is mounted properly. - Replace the scanning lamp heater. - Replace the light control PCB. - Replace the reader controller PCB.

Code: E222-0000

Description: The rise in temperature of the scanning lamp heater is faulty.
During the initial activation after power-on, the reading does not reach 70 deg C within 5 min after the heater is turned on. Or, during standby or reading operation, the reading does not reach 75 deg C within 3 min after the heater is tuned on.
Remedy: - Check if the connecter (J852, J853) of the light control PCB is mounted properly. - Replace the scanning lamp heater. - Replace the light control PCB. - Replace the reader controller PCB.

Code: E240-0000

Description: The communication between the MCON and DCON is faulty.
A communication fault exists between the CPUs of the main controller PCB and the DC controller PCB.
Remedy: - Check the wiring between the DC controller PCB and the main controller PCB. - Replace the DC controller PCB. - Replace the main controller PCB.