Code: E800-0003

Description: The DC relay (RL2) is found to have an open circuit.
Causes: The electric system has an error. The DC controller PCB is faulty.

Code: E800-0004

Description: +24 VRET does not change to +24 V even when the front door, fixing door, and face-down delivery unit are all closed.
Causes: The electric system has an error. The DC controller PCB is faulty.

Code: E805-0001

Description: The fixing fan (FM1) is found to have locked.
Causes: The fixing fan has an error. The delivery fan has an error. The machine cooling fan has an error. The power supply cooling fan has an error. The decurling fan has an error. The kit drive cooling fan has an error. The transfer motor cooling fan has an error.

Code: E805-0002

Description: The delivery fan (FM2) is found to have locked.
Causes: The fixing fan has an error. The delivery fan has an error. The machine cooling fan has an error. The power supply cooling fan has an error. The decurling fan has an error. The kit drive cooling fan has an error. The transfer motor cooling fan has an error.

Code: E805-0003

Description: The machine cooling fan (FM4) is found to have locked.
Causes: The fixing fan has an error. The delivery fan has an error. The machine cooling fan has an error. The power supply cooling fan has an error. The decurling fan has an error. The kit drive cooling fan has an error. The transfer motor cooling fan has an error.

Code: E805-0004

Description: The power supply cooling fan (FM6) is found to have locked.
Causes: The fixing fan has an error. The delivery fan has an error. The machine cooling fan has an error. The power supply cooling fan has an error. The decurling fan has an error. The kit drive cooling fan has an error. The transfer motor cooling fan has an error.

Code: E805-0005

Description: The de-curling fan (FM7) is found have locked.
Causes: The fixing fan has an error. The delivery fan has an error. The machine cooling fan has an error. The power supply cooling fan has an error. The decurling fan has an error. The kit drive cooling fan has an error. The transfer motor cooling fan has an error.

Code: E805-0006

Description: The kit drive cooling fan (FM10) is found to have locked.
Causes: The fixing fan has an error. The delivery fan has an error. The machine cooling fan has an error. The power supply cooling fan has an error. The decurling fan has an error. The kit drive cooling fan has an error. The transfer motor cooling fan has an error.