Code :
  • Code: E711-0002
  • Description: IPC communication error
    Error is detected 4 times or more within 1.5 sec. after communication between the finisher and the printer stops, and recovery ends in failure.
  • Remedy: Check on connection of the cable, Replace the finisher controller PCB, Replace the DC controller PCB
  • Code: E712-0001
  • Description: Communication error between the ADF and the reader
    Communication between the reader and the ADF stops, and the communication cannot recover for 5 sec. or more.
  • Remedy: Check on connection of the cable, Replace the ADF controller PCB, Replace the reader controller PCB
  • Code: E713-0000
  • Description: Communication error between the finisher and the printer
    Communication between the finisher and the copier stops.
  • Remedy: Check on connection of the cable, Replace the finisher controller PCB, Replace the DC controller PCB
  • Code: E717-0001
  • Description: Communication error with the NE controller
    The NE controller connected before the power is turned off fails to be recognized at power-on.
  • Remedy: Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E717-0002
  • Description: Communication error with the NE controller
    A break in the IPC, IPC communication fails to recover
  • Remedy: Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E719-0001
  • Description: Communication error with the coin vender/card reader
    The coin vender connected before the power is turned off fails to be recognized at power-on.
  • Remedy: Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E719-0002
  • Description: Communication error with the coin vender/card reader
    - A break in the IPC cable connected to the coin vender, IPC communication fails to recover - A break in the paper pickup/delivery signal line - Incorrect connection is detected (Short circuit in Tx and Rx of IPC)
  • Remedy: Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
  • Code: E719-0011
  • Description: Communication error with the coin vender/card reader
    The card reader connected before the power is turned off fails to be recognized at power-on.
  • Remedy: Check on connection of the cable To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR