Description: DDI communication error
The reader controller PCB detects communication error between the main controller PCB and the reader controller PCB.
Remedy: Disconnect and then connect the reader communication cable connector, Replace the reader controller PCB, Replace the main controller PCB
Remedy: Disconnect and then connect the main controller PCB (Sub SJ/PE/R), Replace the main controller PCB (Sub SJ/PE/R), Disconnect and then connect the relay PCB (GU-short), Replace the relay PCB (GU-short), Disconnect and then connect the open interface PCB, Replace the open interface PCB, Replace the main controller PCB (main)
Description: Restart in accordance with a change of the product configuration
The BootROM is replaced with a different type (when the PDL option is installed)
Remedy: Turn OFF and back ON the main power to recover