Code: E002-0006

Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 160 deg C within 180 sec after reaching 140 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR

Code: E002-0007

Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 180 deg C within 180 sec after reaching 160 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR

Code: E002-0008

Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach standby temperature (normally 190 deg C) within 180 sec after reaching 180 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR

Code: E002-0101

Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 120 deg C within 300 sec after power-on.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR

Code: E002-0102

Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach standby temperature (normally 190 deg C) within 300 sec after reaching 120 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR

Code: E003-0001

Description: Low temperature of the fixing unit after standby
Abnormal low temperature (130 deg C or lower) of the non-contact thermistor is detected for 3.5 sec continuously after standby.
Remedy: Check on connection of the sub thermistor/thermo switch, Replace the fixing unit, Check on a break in the heater, Replace the cover switch, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR

Code: E004-0001

Description: Error of the protection circuit in the fixing unit
The hardware detects triac short abnormality (1 sec or more) for 400msec continuously while the heater is OFF.
Remedy: Turn OFF and back ON the main power, Check on connection of the thermo switch, Replace the main power supply PCB, Replace the DC controller PCB

Code: E006-0000

Description: Connection error of the fixing unit
The hardware detects non-attachment of the fixing unit for 400msec continuously. A break in the fixing unit presence/ absence signal (FUSER_CNCTX_N) / Disconnection of the connector (The connectors are placed as shown below) DC controller PCB : J316 Fixing unit : J2007, J2008 Relay connector (between DC controller and fixing unit) : J2006 (7 pins)
Remedy: Check on connection of the fixing unit cable, Replace the relay cable, Replace the fixing unit, Replace the DC controller PCB