Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 160 deg C within 180 sec after reaching 140 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 180 deg C within 180 sec after reaching 160 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach standby temperature (normally 190 deg C) within 180 sec after reaching 180 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach standby temperature (normally 190 deg C) within 300 sec after reaching 120 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Low temperature of the fixing unit after standby
Abnormal low temperature (130 deg C or lower) of the non-contact thermistor is detected for 3.5 sec continuously after standby.
Remedy: Check on connection of the sub thermistor/thermo switch, Replace the fixing unit, Check on a break in the heater, Replace the cover switch, Replace the main power supply PCB, Replace the DC controller PCB To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Error of the protection circuit in the fixing unit
The hardware detects triac short abnormality (1 sec or more) for 400msec continuously while the heater is OFF.
Remedy: Turn OFF and back ON the main power, Check on connection of the thermo switch, Replace the main power supply PCB, Replace the DC controller PCB
Description: Connection error of the fixing unit
The hardware detects non-attachment of the fixing unit for 400msec continuously. A break in the fixing unit presence/ absence signal (FUSER_CNCTX_N) / Disconnection of the connector (The connectors are placed as shown below) DC controller PCB : J316 Fixing unit : J2007, J2008 Relay connector (between DC controller and fixing unit) : J2006 (7 pins)
Remedy: Check on connection of the fixing unit cable, Replace the relay cable, Replace the fixing unit, Replace the DC controller PCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.