Description: Abnormality of the fixing unit
A break in the non-contact thermistor case The status that A/D of the non-contact thermistor case is FFh continues for 500msec.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Abnormality of the fixing unit
A short circuit in the non-contact thermistor case The status that film A/D-case A/D of the non-contact thermistor is 0C or more continues for 700msec.
Remedy: Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Abnormality of the fixing unit
A break in the end thermistor The status that A/D of the contact thermistor case is FFh continues for 500msec
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Abnormality of the fixing unit
A short circuit in the end thermistor The status that A/D of the contact thermistor case is 39h or less continues for 500msec.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 70 deg C within 180 sec after reaching 50 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 100 deg C within 180 sec after reaching 70 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 120 deg C within 180 sec after reaching 100 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Description: Insufficient temperature rise of the fixing unit
The non-contact thermistor fails to reach 140 deg C within 180 sec after reaching 120 deg C.
Remedy: Check on connection of the thermistor, Replace the fixing unit To recover from the error: In service mode COPIER>FUNCTION>CLEAR >ERR
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.