Remedy: Check on connection of the token ring board, Replace the token ring board
Code: E746
Description: Option board error
Remedy: Replace with an appropriate UFR PCB. Replace with an appropriate main controller PCB (sub)
Code: E747
Description: Main controller PCB error (Image processing ASIC or memory control/communication control ASIC)
Remedy: Turn the main power off and turn it back on. Disconnect and connect the main controller PCB Replace the main controller PCB (Main).
Code: E748
Description: Main controller PCB error (Image processing ASIC or memory control/communication control ASIC)
Remedy: Disconnect and then connect the main controller PCB (Sub SJA/ PDRM-EF-A/RO-A), Clean the terminal, Replace the main controller PCB (Sub SJ-A/PDRM-EF-A/RO-A), Disconnect and then connect the open interface PCB, Clean the terminal, Replace the open interface PCB, Replace the main controller PCB (main)
Code: E749
Description: Restart in accordance with a change of the product configuration
Remedy: Turn OFF and back ON the main power to recover. Recovered by turning the main power OFF / ON
Code: E804-0000
Description: Controller fan error
Stop of power supply cooling fan was detected
Remedy: Check the connection of power supply cooling fan, replace it
Code: E804-0001
Description: Controller fan error
Stop of power supply cooling fan 2 was detected
Remedy: Check the connection of power supply cooling fan 2, replace it