Description: DDI communication error
When the reader controller PCB has detected trouble in communication between the main controller PCB and reader controller PCB
Remedy: Disconnect and re-connect the reader communication cable connector, or replace the reader controller PCB. Replace the main controller PCB.
Code: E744
Description: Language file/BootROM error
Remedy: Upgrade the language file version.
Code: E747
Description: Main controller PCB error
Remedy: Turn the main power OFF and back ON. Replace the main controller PCB (main). Disconnect and re-connect the main controller PCB (sub R)
Code: E748
Description: Main controller PCB error
Remedy: Disconnect and re-connect the main controller PCBs (sub SJ, PE or R) or replace. Disconnect and re-connect the OPEN interface PCB or replace. Replace the main controller PCB (main).
Code: E749-0001
Description: Instruction to restart accompanying change in product configuration
When the existing BootROM has been replaced with the BootROM of a different kind (when a PDL option was installed, etc.)
Remedy: Reset by turning the main power OFF and back ON.
Code: E749-1001
Description: Instruction to restart accompanying change in product configuration
Error where SDRAM memory as high as 1 GB remains although the controller board version is an old one
Remedy: Check the combination of the main controller PCB and SDRAM.
Code: E751-00Xx
Description: Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Trouble in the drum unit connections (trouble at the printer side)
Remedy: Check the drum unit connections or replace the unit.
Code: E751-01Xx
Description: Drum Unit / Faulty Connection of the Toner Receptacle See below X: reading=1, writing=2 x indicates color [Y=1, M=2, C=3, K=4]
Write error in the memory inside the drum unit
Remedy: Check the drum unit connections or replace the unit.