Description: Error in communication between main controller and DC controllerWhen the response from the DC controller does not arrive within the prescribed period of time during printing
Remedy: Check the connector connections. Check the DC controller PCB (MAISY). Replace the No.1 main controller circuit.
Description: Main controller PCB error
When a communication error has occurred in the main controller PCB at startup
Remedy: Check the connections between the main controller PCB and main controller PCB (sub). Replace the main controller PCB. Replace the main controller PCB (sub).
Description: Feeder communication error
Checksum error
Remedy: Check the connections between the ADF controller PCB and main controller PCB (sub). Replace the ADF controller PCB. Replace the main controller PCB (sub).
Description: Feeder communication error
Reception status error
Remedy: Check the connections between the ADF controller PCB and main controller PCB (sub). Replace the ADF controller PCB. Replace the main controller PCB (sub).