Description: A fault has occurred in image processing within the controller
Causes:
Remedy: 1. Turn off and then back on the power. 2. If remedy 1 above fails, increase the memory. 3. If remedy 2 above fails, replace the controller board.
Causes: The temperature of the fixing unit does not reach the targeted temperature -10 deg C within 63 sec. after the wait sequence is started. Cause The fixing film unit is faulty. The engine controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the engine controller PCB.
Causes: The fixing unit temperature is monitored every 5 msec., and the temperature exceeds 220 deg C for 30 times continuously. Cause The main thermistor is faulty. The engine controller PCB is faulty.
Remedy: - Replace the fixing film unit. - Replace the engine controller PCB.
Causes: The temperature of the thermistor is detected every 5 msec. during the control and it shows under 20 deg C for 100 times continuously after the temperature of the fixing unit exceeds 50 deg C at least once. Cause The main thermistor is faulty. The engine controller PCB is faulty. The connector is in poor contact. The harness is faulty.
Remedy: - Replace the fixing film unit. - Replace the engine controller PCB.