Code: E825-0003

Description: Drum phase control sensor failure warning
Causes: Black drum phase control sensor failure warning A slit was not detected for 4 seconds after slit detection started. An abnormal slit width was detected.
Remedy: Check the Bk drum drive gear. Replace the Bk drum HP sensor (PS12).

Code: E825-0004

Description: Drum phase control sensor failure warning
Causes: OHT sensor failure warning
Remedy:

Code: E840-0000

Description: Pressure release mechanism failure
Causes: The target pressure position was not reached even when 3.5 seconds (approximately 1.5 rotation of the cam) elapsed after start of the fixing motor reverse rotation.
Remedy: Check the gears and detection flags related to fixing pressure release mechanism. Replace the fixing pressure release sensor (PS9). Replace the fixing motor. Replace the fixing assembly.