Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in black scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: assembly. Cause Failure in laser scanner unit, failure in DC controller PCB. - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Causes: If CPR sensor is judged error. Cause Soiling in density detection sensor, failure in density detection sensor, failure in DC controller PCB, failure in toner cartridge.
Remedy: - Check the connector of DC controller PCB - Replace the ITB unit - Replace the DC controller PCB - Replace the toner cartridge
Causes: Error between DC controller PCB and main controller PCB. Cause Failure in connection between PCB, failure in DC controller PCB, failure in controller PCB.
Remedy: - Check the connection of the connector of the DC controller PCB and controller PCB - Replace the DC controller PCB - Replace the controller PCB