Description: Error in the environment detection sensor
Causes: Error in the environment detection sensor Cause Failure in environment detection sensor, failure in DC controller PCB
Remedy: - Check the connectors of the environment detection sensor and DC controller PCB - Replace the environment detection sensor - Replace the DC controller PCB
Description: Error in primary transfer disengagement.
Causes: Primary transfer disengagement mechanism did not work properly. Cause Disengagement mechanism error, ITB Tension Sensor error, Pickup Motorerror, DC Controller PCB error
Remedy: - Check the disengagement mechanism. - Check the connectors of the ITB Tension - - Sensor, Pickup Motor and the DC Controller PCB (J167, J202, J160, J201, J140). - Replace the ITB Tension Sensor. - Replace the Pickup Motor. - Replace the DC Controller PCB.
Description: Error in primary transfer disengagement.
Causes: Primary transfer disengagement mechanism did not work properly. Cause Disengagement mechanism error, ITB Tension Sensor error, Pickup Motor error, DC Controller PCB error
Remedy: - Check the disengagement mechanism. - Check the connectors of the ITB Tension Sensor, Pickup Motor and the DC Controller PCB (J167, J202, J160, J201, J140). - Replace the ITB Tension Sensor. - Replace the Pickup Motor. - Replace the DC Controller PCB.
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in yellow scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: assembly. Cause Failure in laser scanner unit, failure in DC controller PCB. - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in magenta scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB.
Remedy: assembly. Cause Failure in laser scanner unit, failure in DC controller PCB. - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Description: Error in scanner motor, laser unit, and BD.
Causes: Breakdown in cyan scanner assembly. Cause Failure in laser scanner unit, failure in DC controller PCB
Remedy: assembly. Cause Failure in laser scanner unit, failure in DC controller PCB. - Check the connectors of the laser scanner unit and DC controller PCB - Replace the laser scanner unit - Replace the DC controller PCB
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.