Description: Abnormal high temperature of Fixing Assembly (caused by Sub Thermistor)
Causes: It was detected that the temperature of the Sub Thermistor of the Fixing Assembly was abnormally high.
Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Description: Abnormal low temperature of Fixing Assembly
Causes: It was detected that the temperature of the Fixing Assembly was abnormally low.
Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Description: Abnormal low temperature of Fixing Assembly (caused by Sub Thermistor)
Causes: It was detected that the temperature of the Sub Thermistor of the Fixing Assembly was abnormally low.
Remedy: 1. Check the connector between the Fixing Assembly and the DC Controller PCB. 2. Replace the Fixing Assembly. 3. Replace the DC Controller PCB.
Description: Error in fixing power supply drive circuit
Causes: The zero cross signal was not detected for the specified period of time or more.