Causes: The Duplex Cooling Fan failed to rotate at the specified revolution.
Remedy: 1. Check the connector between the Duplex Cooling Fan and the DC Controller PCB. 2. Replace the Duplex Cooling Fan. 3. Replace the DC Controller PCB.
Description: Fixing Power Supply Cooling Fan error
Causes: The Fixing Power Supply Cooling Fan failed to rotate at the specified revolution.
Remedy: 1. Check the connector between the Fixing Power Supply Cooling Fan and the DC Controller PCB. 2. Replace the Fixing Power Supply Cooling Fan. 3. Replace the DC Controller PCB.
Description: Low-voltage power supply failure detection
Causes: Printer detected low-voltage power supply failure.
Remedy: 1. Check the connector between the Power Supply Unit and the DC Controller PCB. 2. Replace the Power Supply Unit. 3. Replace the DC Controller PCB.