  • Code: E204
  • Description: The scanner leading edge signal (SCDP1) is not generated within 0.8 sec after the scanner has started to move
  • Code: E209
  • Description: The scanner C.F.F. position signal (SCFFP) is not generated within 10 sec after the C.F.F. has been sent.
  • Code: E210
  • Description: The lens X home position signal (SCFFP) is not generated within 10 sec after the C.F.F. has been sent.
  • Code: E212
  • Description: The lens Y home position signal (LYHP) is not generated within 9 sec after the power switch or the Copy Start Key is turned ON. The lens Y home position signal (LYHP) is generated for 2 sec or more.
  • Code: E213
  • Description: In stream reading mode, the scanner original leading edge sensor 2 signal (SCDP2) is not generated for 5 pages continuously.
  • Code: E214
  • Description: While the scanner cooling fan (FM1, FM10, FM11) is rotating, an error signal is generated for 2 sec or more.
  • Code: E270
  • Description: In stream reading mode, the scanner leading edge signal(SCDP2) is not generated within a specific period of time after a command has been issued to lock the scanner.
  • Code: E710
  • Description: At power-on the IPC (Q170) on the DC controller PCB cannot be initialized.