Remedy: 1 CRU SENSOR ASSY is defective. With Imaging Cartridge installed, confirm that current flows between pins 1 and 2 of connector CN216 on the C232 MAIN board. Replace the CRU SENSOR ASSY. 2 ROS ASSY is defective. With power on, confirm that the voltage across pins 1 and 3 of connector P/J111 on the LD board (mounted on the ROS ASSY) is +5V. Replace the ROS ASSY. 3 LVPS ASSY is defective. Confirm that the LD ASSY is receiving power. Replace the LVPS ASSY.
Remedy: 1 CRU SENSOR ASSY is defective. With Imaging Cartridge installed, confirm that current flows between pins 1 and 2 of connector CN216 on the C232 MAIN board. Replace the CRU SENSOR ASSY. 2 ROS ASSY is defective. With power on, confirm that the voltage across pins 1 and 3 of connector P/J111 on the LD board (mounted on the ROS ASSY) is +5V. Replace the ROS ASSY. 3 LVPS ASSY is defective. Confirm that the LD ASSY is receiving power. Replace the LVPS ASSY.
Description: Communication Error (between main control circuit and engine control circuit)
Remedy: 1 C232 MAIN board is defective (This error indicates that there is a problem in communication between the main-control CPU and the engine-control CPU. Both of these CPUs are mounted on the C232 MAIN board.) Replace the board.