Remedy: 1 EEPROM is defective. Initilialize EEPROM from the panel, then check operation. Replace the EEPROM. 2 C232 MAIN board is defective Replace the board
Remedy: 1 EEPROM is defective. Initilialize EEPROM from the panel, then check operation. Replace the EEPROM. 2 C232 MAIN board is defective Replace the board
Remedy: 1 Thermistor is defective. Does error occur immediately following power-on? • Guideline: Thermistor resistance should be between 200 and 350 KΩ when FUSER ASSY has been left at room temperature (18 to 20°C). Replace the thermistor. 2 Heater lamp is burned out. Confirm that heater lamp comes on when power is switched on with FUSER ASSY in cooleddown state. Replace the heater lamp. 3 Thermal fuse is severed. Check conductance through the thermal fuse at normal temperature Replace the fuse. 4 LVPS ASSY is defective. Confirm that voltage at pin 5 of connector CN210 (on the C232 MAIN board) is 0V at start of warm-up. Replace the LVPS ASSY.
Remedy: 1 DRIVE ASSY not operating correctly. Remove the fuser unit and Imaging Cartridge, then rotate the DRIVE ASSY gear by hand. Confirm that the gear turns smoothly. Replace the DRIVE ASSY 2 DRIVE ASSY is defective. Check the resistance of the motor coil. The resistance should be 1 to 3W. Replace the DRIVE ASSY. 3 LVPS ASSY is defective. Confirm +24VDC with Imaging Cartridge removed and INTERLOCK SW=ON. Replace the LVPS ASSY.
Remedy: 1 Fan is defective. Confirm that fan comes on at power-on. Replace the fan. 2 LVPS ASSY is defective. Confirm that pin 1 of LVPS connector P/J102 is at +24V. Replace the LVPS ASSY.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.