Causes: An error occurred in the carriage operating sequence.
Remedy: See Remedy for DC error (CR motor)
Code: 61H
Description: PW detection error (Low check error)
Causes: PW detector trouble
Remedy: • Checking the PW Sensor • Checking the PW Sensor for adhesion of dirt and dust • Checking the connection of the FFC • Making the following adjustments: • PW adjustment • Checking the following parts and replace the defective one: • Head FFC • Carriage Assy • Main Board • Power Supply Board
Remedy: • Checking the operation of the actuator and the connection of the connector. • Checking the following parts and replace the defective one: • Sensor • Main Board • Power Supply Board
Code: 63H
Description: Paper detection error
Causes: Sensor trouble
Remedy: • Checking the operation of the actuator and the connection of the connector. • Checking the following parts and replace the defective one: • Sensor • Main Board • Power Supply Board
Code: 70H
Description: APG error (normal drive error)
Causes: An error occurred in the APG operating sequence
Remedy: • Checking the installation of the APG Sensor: position of the sensor and connection of the connector (CN7) • Checking the drive of the APG Assy • Installation of the composite gear of the ASF Assy -APG Assy • Standalone operation of the APG Assy • Reinstallation of the APG Assy • Checking the following parts and replace the defective one: • APG Assy • ASF Assy • APG Sensor • PG Left Cam • Main Board • Power Supply Board
Code: 71H
Description: APG home seek error
Causes: An error occurred in the APG operating sequence
Remedy: • Checking the installation of the APG Sensor: position of the sensor and connection of the connector (CN7) • Checking the drive of the APG Assy • Installation of the composite gear of the ASF Assy -APG Assy • Standalone operation of the APG Assy • Reinstallation of the APG Assy • Checking the following parts and replace the defective one: • APG Assy • ASF Assy • APG Sensor • PG Left Cam • Main Board • Power Supply Board
Code: 72H
Description: Error in APG drive by factory command
Causes: An error occurred in the APG operating sequence
Remedy: • Checking the installation of the APG Sensor: position of the sensor and connection of the connector (CN7) • Checking the drive of the APG Assy • Installation of the composite gear of the ASF Assy -APG Assy • Standalone operation of the APG Assy • Reinstallation of the APG Assy • Checking the following parts and replace the defective one: • APG Assy • ASF Assy • APG Sensor • PG Left Cam • Main Board • Power Supply Board
Code: 88H
Description: Inserted tray error during cleaning
Causes: An error occurred during cleaning
Remedy: • Pulling out the CDR Tray • Checking the CDR Tray Sensor • Checking the CDR Tray Sensor for adhesion of dirt or dust • Checking the connection of the connector of the CDR Tray Sensor • Checking the connection of the FFC • Checking the following parts and replace the defective one: • CDR Tray Sensor • CDR Tray