Các lỗi thường gặp

Code :
  • Code: 89H
  • Description: Overhit detection error during cleaning
  • Causes: An error occurred during cleaning
  • Remedy: • Checking the operation of the Carriage Assy; Move the Carriage Assy by hand, and check to see if it moves smoothly. • Checking the following parts and replacing the defective one: • Checking the lead wires of the CR Motor (CN14) for disconnection or breakage • Checking the CR Encoder FFC (CN1) for disconnection or breakage • Checking the printer frame for adhesion of dirt or insufficient lubrication • Checking the CR Guide Shaft for adhesion of dirt or insufficient lubrication • Checking the Linear Scale for adhesion of dirt or damage • Checking the CR Encoder for adhesion of dirt or damage • Checking the CR Belt for damage or improper tension • Checking the CR Motor and replacing it if necessary • Main Board
  • Code: A0H
  • Description: Waste ink overflow
  • Causes: Life expiration of maintenance parts
  • Remedy: Replace all the maintenance parts, and clear the maintenance counter.
  • Code: D1H
  • Description: CR drive time-out
  • Causes: The motor kept operating for more than the specified time.
  • Remedy: • Checking the mechanism and operation: Check the mechanism and operation of the motor in question. • Checking the connection of the connectors and routing of the lead wires • Checking the motor in question and the following parts and replacing the defective part: • Main Board • Power Supply Board
  • Code: D2H
  • Description: CR (load positioning) drive time-out
  • Causes: The motor kept operating for more than the specified time.
  • Remedy: • Checking the mechanism and operation: Check the mechanism and operation of the motor in question. • Checking the connection of the connectors and routing of the lead wires • Checking the motor in question and the following parts and replacing the defective part: • Main Board • Power Supply Board
  • Code: D3H
  • Description: PF drive time-out
  • Causes: The motor kept operating for more than the specified time.
  • Remedy: • Checking the mechanism and operation: Check the mechanism and operation of the motor in question. • Checking the connection of the connectors and routing of the lead wires • Checking the motor in question and the following parts and replacing the defective part: • Main Board • Power Supply Board
  • Code: D4H
  • Description: PF (BS) drive time-out
  • Causes: The motor kept operating for more than the specified time.
  • Remedy: • Checking the mechanism and operation: Check the mechanism and operation of the motor in question. • Checking the connection of the connectors and routing of the lead wires • Checking the motor in question and the following parts and replacing the defective part: • Main Board • Power Supply Board
  • Code: EFH
  • Description: Position error in PF BS control
  • Causes: An error occurred in the PF motor operating sequence
  • Remedy: • Checking the PF mechanism by visual inspection: Check the PF mechanism for paper jam or adhesion of foreign matters by visual inspection. • Checking the operation of the PF mechanism: Operate the PF mechanism by hand, and check to see if it operates smoothly. • Making the following adjustments: • Bi-D • Paper feed length with PF Assy • Paper feed length with Eject Assy • PW adjustment • Checking the following parts and replace the defective one: • Checking the PF Encoder FFC (CN8) for disconnection or breakage • Checking the lead wires of the PF Motor (CN13) for disconnection or breakage • Checking the PF scale for adhesion of dirt or damage • Checking the PF encoder for adhesion of dirt or damage • Checking the Upper Paper Guides for improper installation • Checking the PF Motor and replacing it if necessary • Main Board • Power Supply Board
  • Code: F0H
  • Description: DTY_max error in PF BS control
  • Causes: An error occurred in the PF motor operating sequence
  • Remedy: • Checking the PF mechanism by visual inspection: Check the PF mechanism for paper jam or adhesion of foreign matters by visual inspection. • Checking the operation of the PF mechanism: Operate the PF mechanism by hand, and check to see if it operates smoothly. • Making the following adjustments: • Bi-D • Paper feed length with PF Assy • Paper feed length with Eject Assy • PW adjustment • Checking the following parts and replace the defective one: • Checking the PF Encoder FFC (CN8) for disconnection or breakage • Checking the lead wires of the PF Motor (CN13) for disconnection or breakage • Checking the PF scale for adhesion of dirt or damage • Checking the PF encoder for adhesion of dirt or damage • Checking the Upper Paper Guides for improper installation • Checking the PF Motor and replacing it if necessary • Main Board • Power Supply Board