Code :
  • Code: 00010010
  • Display: SERVICE CALL 00010010: PF MOTOR OVER HEAT (PWM OUTPUT MALFUNCTION)
  • Description: Load continues to be linked to the PF motor/PWM output abnormal
  • Remedy: • PF timing belt tension confirmation/adjustment • PF roller and PF roller subordinate movement. • PF timing belt exchange • PF motor exchange • C362DRV board exchange
  • Code: 00010012
  • Display: SERVICE CALL 00010012: CAP HOME POSITION ERROR
  • Description: Starting point detection error or cap starting point sensor defective treatment by cap motor step-out
  • Remedy: • Cable splicing confirmation between the cap starting point sensor and CSCI board • Cleaning of the cap starting point sensor • Cleaning unit exchange
  • Code: 00010013
  • Display: SERVICE CALL 00010013: SUPPLY SYSTEM (INK PUMP) HOME POSITION ERROR
  • Description: It is defective the starting point detection error or supply system starting point sensor by the motor step-out of ink pump Assy.
  • Remedy: • Supply system motor exchange • Supply system starting point sensor exchange • C362DRV board exchange
  • Code: 00010014
  • Display: SERVICE CALL 00010014: PRESSURE DEFECTIVE ERROR
  • Description: It is defective the pressure detection error or pressure sensor by supply system motor step-out.
  • Remedy: • Regulator valve solenoid exchange • Supply system motor exchange • Sensor exchange • C362DRV board exchange
  • Code: 0001001A
  • Display: OVERFLOW SERVICE CALL 0001001A: INK SURFACE SENSOR (Y) OVERFLOW
  • Description: Surface of a liquid sensor defective or I/C valve solenoid defective it is (on condition).
  • Remedy: • I/C valve solenoid exchange • C362DRV board exchange • Surface of a liquid sensor exchanger
  • Code: 0001001B
  • Display: SERVICE CALL 0001001B: HEAD DRIVER (TG) TEMPERATURE ERROR
  • Description: Head failure or head cable splicing defective/breaking of wire
  • Remedy: • Head cable joint • Head Assy exchange
  • Code: 0001001C
  • Display: SERVICE CALL 0001001C: SUCTION FAN HOME POSITION ERROR
  • Description: Starting point detection error or shutter starting point sensor defective o treatment by shutter motor step-out.
  • Remedy: • Adsorption fan shutter motor exchange • C362DRV board exchange • Shutter starting point sensor exchange
  • Code: 0001001D
  • Display: SERVICE CALL 0001001D: CR SERVO PARAMETER ERROR
  • Description: Load continues to be linked to the CR motor. /CR motor defective.
  • Remedy: • Do the same correspondence as service call 00010004.