Display: SERVICE CALL 0001001E: PF SERVO PARAMETER ERROR
Description: Load continues to be linked to the PF motor. / PF motor defective
Remedy: • Do the same correspondence as service call 00010000.
Code: 00010020
Display: SERVICE CALL 00010020: CSIC READ INFORMATION ERROR
Description: The information of CSIC (the ink cartridge) is not correct.
Remedy: • Ink cartridge is installed/ exchange
Code: 00010021
Display: SERVICE CALL 00010021: STARTER CARTRIDGE ERROR
Description: When it is neutral ink seed I led it. The CSIC information of liquid crystal ink cartridge is not correct.
Remedy: • Ink cartridge is installed / exchange
Code: 00010022
Display: SERVICE CALL 00010022: INK TYPE ERROR
Description: It is the binding other than dye/pigment. "Without being related to binding" CSIC detection: off it is to" "ink seed neutral.
Remedy: • Correct ink cartridge is fixed. The ink seed is bound with the maintenance mode while the lever is canceled.
Code: 00020000
Display: SERVICE CALL:00020000 (NVRAM ERROR)
Description: Abnormal detection in a corresponding element
Remedy: • Staying the error code that occurred n it confirms whether the error reclosing same the power supply occurs once again. In the case that there is reproducibility I exchange the C362DRV board.
Code: 00020001
Display: SERVICE CALL: 00020001 (INTERNALSUM ERROR)
Description: Abnormal detection in a corresponding element
Remedy: • Staying the error code that occurred n it confirms whether the error reclosing same the power supply occurs once again. In the case that there is reproducibility I exchange the C362DRV board.
Code: 00020002
Display: SERVICE CALL: 00020002 (SDRAM ERROR)
Description: Abnormal detection in a corresponding element
Remedy: • Staying the error code that occurred n it confirms whether the error reclosing same the power supply occurs once again. In the case that there is reproducibility I exchange the C362DRV board.
Code: 00020003
Display: SERVICE CALL:00020003 (FLASH MEMORY SUM ERROR)
Description: Abnormal detection in a corresponding element
Remedy: • Staying the error code that occurred n it confirms whether the error reclosing same the power supply occurs once again. In the case that there is reproducibility I exchange the C362DRV board.