Code: 1A23

Description: RTC analysis error
The value information on various absolute time stored on NVRAM is abnormal.
Remedy: Check if the lithium battery is installed properly. Replace the MAIN BOARD ASSY .

Code: 1A26

Description: RTC communication error
The communication with the RTC circuit cannot be made.
Remedy: Replace the MAIN BOARD ASSY .

Code: 1A37

Description: Head thermistor error
There is something wrong with the Head FFC connection. The Head Thermistor detects a temperature out of the specification. The Head Thermistor has a defect.8).
Remedy: Check whether the Head FFC is properly connected. If not (slant connection or the like), correct it. Replace the PRINT HEAD(s) .

Code: 1A38

Description: Transistor thermistor error
The transistor is faulty. The thermistor detects a temperature out of the specification.
Remedy: Replace the PRINT HEAD(s) .

Code: 1A39

Description: Head error
The active signal of head error has been detected.
Remedy: Replace the PRINT HEAD(s) .

Code: 1A40

Description: MAIN BOARD ASSY IC2 error
The active signal of head error has been detected.
Remedy: Replace the PRINT HEAD(s) .

Code: 1A41

Description: Head rank ID input error
The information of the Head rank ID is wrong.
Remedy: Configure the head rank ID again.

Code: 2000

Description: NVRAM error
NVRAM erase or write error has occurred.
Remedy: Replace the MAIN BOARD ASSY .