Code: 2003

Description: Boot program sum error
Installation of the firmware has been failed. The Flash ROM is faulty.
Remedy: Install the main firmware again. Replace the MAIN BOARD ASSY . Replace the MAIN BOARD ASSY .

Code: 200A

Description: Program loading error
The SDRAM is faulty. The program cannot be loaded on the SDRAM.
Remedy: Replace the MAIN BOARD ASSY .

Code: 200B

Description: Internal insufficient memory error
The main firmware has a defect.
Remedy: Install the correct main firmware.

Code: 200C

Description: Servo interrupt watchdog time-out error
The servo cannot be controlled.
Remedy: Install the correct main firmware. Replace the MAIN BOARD ASSY .

Code: 200D

Description: System interrupt watchdog timeout error
A system failure such as CPU failure, defective cash or the like has occurred.
Remedy: Replace the MAIN BOARD ASSY .

Code: 200E

Description: Unknown NMI
The CPU has detected an unknown NMI.
Remedy: Replace the MAIN BOARD ASSY .

Code: 3000

Description: AC power shut-off
The AC power has been shut off due to a power failure, unplugged, P/S BOARD ASSY failure, or MAIN BOARD ASSY failure or the like.
Remedy: Check whether the AC cable is properly connected. If not, correct it. Replace the P/S BOARD ASSY . Replace the MAIN BOARD ASSY .

Code: FXXX

Description: CPU-related error
The firmware has a defect. The MAIN BOARD ASSY is broken.
Remedy: Install the correct main firmware. Replace the MAIN BOARD ASSY .