Description: Pressurizing initialization error
The initialization process did not complete within a predetermined time period.
Remedy: 1. Replace the Pressure Unit (IC Holder). 2. Replace the Main Board.
Code: 1621
Description: Pressurizing/Suction switching error
The pressurizing and suction processes did not complete within a predetermined time period.
Remedy: 1. Replace the Pressure Unit (IC Holder). 2. Replace the Main Board.
Code: 1622
Description: Operating time-out error
The switching operation did not complete within a predetermined time period.
Remedy: 1. Replace the Pressure Unit (IC Holder). 2. Replace the Main Board.
Code: 1623
Description: Continuous revolution error
The control terminal (Vre terminal) of the Pressure Motor driver has shorted out.
Remedy: 1. Remove the foreign material. 2. If the error still occurs, replace the Main Board.
Code: 1930
Description: Pre Heater AD abnormal error
A thermistor temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor . 2. Replace the Main Board.
Code: 1931
Description: HTC common elements communication error
• Connection failure between the Main Board and Sub-E Board such as cable disconnection • There is something wrong with the elements on the Sub-E Board. • There is something wrong with the communication elements on the Main Board.
Remedy: 1. Reconnect the cable. 2. Replace the cable. 3. Replace the Sub-E Board. 4. Replace the Main Board.
Code: 1932
Description: Pre Heater overheat error
A heater temperature out of a predetermined range was detected the predetermined number of times in a row.
Remedy: 1. Replace the thermistor . 2. Replace the Main Board.
Code: 1933
Description: Pre Heater heat deviation error
The difference between the current temperature and target temperature exceeded a predetermined limit.
Remedy: 1. Replace the thermistor . 2. Replace the Main Board.