Các lỗi thường gặp

Code :
  • Code: 54.20.00
  • Display: 54.20.00 PRINTER ERROR
  • Description: Printing cannot continue. The CPR sensor out of range.
  • Remedy: 1 For step-by-step information, press GO. 2 Turn the printer off and then on.
  • Code: 54.X
  • Display: 54.X PRINTER ERROR
  • Description: X Description: 1 low fuser temperature 3 Dmax density sensor 5 CPR sensor 6 OHT sensor 7 yellow drum phase (home) position sensor 8 magenta drum phase (home) position sensor 9 cyan drum phase (home) position sensor 10 black drum phase (home) position sensor 11 yellow density sensor 12 magenta density sensor 13 cyan density sensor 14 black density sensor 15 yellow CPR sensor 16 magenta CPR sensor 17 cyan CPR sensor 18 black CPR sensor 19 ETB speed control sensor 20 color-plane-registration sensor 21 black toner-level sensor 1E or 30 halftone calibration error 01 humidity environmental sensor abnormal
  • Remedy: Turn the printer off and then on, and then check the following items in the order listed. 54.1 error: Check the fuser. See 50.X fuser error. 54.3 error: Check the connections. Replace the color registration detection assembly. 54.5 error: Check the connections. Replace the color registration detection assembly. 54.6 error: Check the connections. Replace the paper pickup unit. 54.7, 54.8, 54.9, or 54.10 error: Check the connections. Replace the drum-phase sensor for the indicated color. 54.11, 54.12, 54.13, or 54.14 error: Check the connections. Check the cartridge and replace it if necessary. Replace the color-registration detection assembly. 54.15, 54.16, 54.17, 54.18: Check the connections. Replace the color registration detection assembly. 54.19 error: Check the ETB connection. Replace the ETB. Replace the DC controller. Calibrate the printer. 54.20 error: Check the connection. Replace the color-registration detection assembly. 54.21, 54.22, 54.23, or 54.24 error: Check the connections. Replace the toner-level sensing PCA. Replace the DC controller. Calibrate the printer.
  • Code: 54.XX.00
  • Display: 54.XX.00 PRINTER ERROR
  • Description: Printing cannot continue. The CPR sensor out of range. X values 15 = yellow 16 = magenta 17 = cyan 18 = black
  • Remedy: 1 For step-by-step information, press GO. 2 Turn the printer off and then on.
  • Code: 55.01.XY
  • Display: 55.01.XY DC CONTROLLER ERROR
  • Description: The DC controller is not communicating with the formatter. The problem could be caused by a timing error or an intermittent connection.
    X Description: 0 communication error 1 DC controller memory error 2 outgoing party error 3 no engine response 4 communication timeout
  • Remedy: 1 Press GO to continue. 2 Turn the printer off and then on. 3 Reseat or replace the connectors between the DC controller and the formatter. 4 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller. 5 Replace the formatter. Initialize NVRAM.
  • Code: 56.XX
  • Display: 56.XX PRINTER ERROR
  • Description: A printer error has occurred.
    XX Description: 01 illegal input 02 illegal output
  • Remedy: Turn the printer off then on again. If the error persists, record the message and call support.
  • Code: 57.X
  • Display: 57.X PRINTER ERROR
  • Description: A printer-fan error has occurred.
    X Description: 3 cartridge fan (vertical fan, F2) 4 formatter fan (horizontal fan, F1) 7 power supply fan (F3; HP Color LaserJet 4650 models)
  • Remedy: Turn the printer off and then on. 57.3 Cartridge fan error (F2) 1 Reconnect the connector J1004 on the DC controller PCA. 2 Immediately after starting the print operation, measure the voltage between pins 1 and 3 on the J1004 connector. If the voltage changes from 0 V to 24 V, replace the cartridge fan. 3 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller 57.4 Formatter fan error (F1) 1 Reconnect the connector J1003 on the DC controller PCA. 2 Immediately after turning the printer on, measure the voltage between pins 1 and 3 on the J1004 connector. If the voltage changes from 0 V to 24 V, replace the formatter fan. 3 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller. 57.5 Power-supply fan error (F3) (HP Color LaserJet 4650 models) 1 Reconnect the connector J1037 on the DC controller PCA. 2 Immediately after turning the printer on, measure the voltage between pins 1 and 3 on the J1037 connector. If the voltage changes from 0 V to 24 V, replace the powersupply fan. 3 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller.
  • Code: 58.X
  • Display: 58.X PRINTER ERROR
  • Description: A memory tag error was detected.
    X Description: 2 air-temperature sensor 3 CPU 4 power supply
  • Remedy: 1 Turn the printer off and then on. 2 Replace the memory PCA. 3 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller
  • Code: 59.XY
  • Display: 59.XY PRINTER ERROR
  • Description: A printer motor error has occurred.
    X Description: 0 motor error 1 motor startup error 2 motor rotation error 3 fuser motor startup error 4 fuser motor rotation error 5 print cartridge motor startup error 6 print cartridge motor rotation error 9 ETB motor startup error A ETB motor rotation error B developing disengaging motor startup error C developing disengaging motor rotation error
    Y Description: 0 no color/black 1 cyan 2 magenta 3 yellow
  • Remedy: 1 Turn the printer off and then on. 2 This message might also appear if the transfer unit is missing or incorrectly installed. Ensure that the transfer unit is correctly installed. ETB motor error 1 Clean the ETB unit intermediate connector, J4017. . 2 Reconnect the connectors J4022 for the ETB motor, J4017 between the ETB and the printer, and J4014 on the DC controller PCA. 3 Replace the ETB motor. 4 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller. Fuser motor error 1 Reconnect the connectors J4030 for the fuser motor and J1002 on the DC controller PCA. 2 Replace the fuser drive assembly. 3 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller. Print cartridge motor error 1 Reconnect the print cartridge connector on the DC controller PCA (J1013 for cyan, J1031 for magenta, J1032 for yellow, and J1033 for black). 2 Replace the drum drive assembly for the indicated print cartridge. 3 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller. Developing-disengaging motor error 1 Reconnect the connectors J4024 and J1019 between the developing-disengaging motor and the DC controller PCA. 2 Replace the developingdisengaging drive assembly. 3 Replace the DC controller PCA. Calibrate the printer after replacing the DC controller.