Remedy: 1. Turn the product off and then on. 2. Determine if the scanner lamp turns on and off approximately 12 second after the product turns on. 3. If the lamp does not turn on and then off: a. View the lamp through the glass to determine if it is broken. Replace the lamp if it is broken. b. Re-seat the cables from the lamp to the inverter. c. Replace the inverter. 4. If the lamp does turn on and then off: a. Reseat the FFC interconnect between the optical carriage and the SCB. b. Replace the optical carriage. c. Replace the SCB.
Remedy: 1. Turn the product off and then on. 2. Check the CPB LED. 3. Verify that the CPB connections are correct. 4. Verify the cable from the scanner to the formatter is not plugged in backwards. 5. Replace the CPB.
Description: There was an AFE1 (analog front-end) failure.
Remedy: 1. Turn the product off and then on. 2. Check the flat cables on the SCB. 3. Check the LEDs on the SCB. 4. Replace the SCB. 5. Replace the scanner
Remedy: 1. Turn the product off and then on. 2. Check the flat cables on the SCB. 3. Check the LEDs on the SCB. 4. Replace the SCB. 5. Replace the scanner.
Remedy: 1. Check the SCB and CPB LEDs to verify that the scanner has power. 2. Verify that the scanner power cable is connected to the scanner power supply and fuser power supply. 3. Replace the CPB.