Remedy: 1. Reinstall the fuser. Check the connector (J704) between the fuser and the product. If it is damaged, replace the fuser drive unit or fuser. 2. Reconnect the connector (J131A) on the DC controller PCA. 3. Replace the fuser.
Remedy: 1. Check the power source at the product location. NOTE: If the product does not meet the power requirement of 43 to 57Hz frequency, the fuser temperature control does not work correctly and this causes malfunction. 2. Reconnect the connector (J21) on the DC controller PCA. 3. Replace the low-voltage power supply unit.
Description: The fuser is defective (pressure release mechanism abnormality).
Remedy: 1. Reconnect the connector (J181) on the DC controller PCA. 2. Run the sensor test in the sensor monitor mode to verify that the fuser pressure release sensor is functioning correctly. If it is not, replace the fuser pressure release sensor unit. 3. Check the fuser pressure release sensor flag. If it is damaged, replace the fuser. 4. Run the fuser pressure release drive test in the actuator drive mode to verify that the fuser motor is functioning correctly. If it is not, replace the fuser motor. 5. Replace the fuser.
Description: Abnormally low subthermistor fuser temperature error.
Remedy: 1. Remove the fuser and remove any residual media in the fuser. 2. Reinstall the fuser. Check the connector (J704) between the fuser and the product. If it is damaged, replace the fuser drive unit or fuser. 3. Reconnect the connector (J131A) on the DC controller PCA and the connectors (J109, J110) on the power line between the low-voltage power supply unit and fuser. 4. Replace the fuser.
Description: Abnormally high subthermistor fuser temperature error.
Remedy: 1. Reinstall the fuser. Check the connector (J704) between the fuser and the product. If it is damaged, replace the fuser drive unit or fuser. 2. Reconnect the connector (J131A) on the DC controller PCA. 3. Replace the fuser.
Description: The product has experienced an internal error with a laser scanner.
black
Remedy: 1. Turn the product off and then on. 2. Verify that the connectors J61 and J62 on the DC controller PCA are correctly seated. Also verify that the connectors on the laser scanner are correctly seated. 3. If the problem remains, replace the laser scanner.
Description: The product has experienced an internal error with a laser scanner.
cyan
Remedy: 1. Turn the product off and then on. 2. Verify that the connectors J61 and J62 on the DC controller PCA are correctly seated. Also verify that the connectors on the laser scanner are correctly seated. 3. If the problem remains, replace the laser scanner.
Description: The product has experienced an internal error with a laser scanner.
magenta
Remedy: 1. Turn the product off and then on. 2. Verify that the connectors J61 and J62 on the DC controller PCA are correctly seated. Also verify that the connectors on the laser scanner are correctly seated. 3. If the problem remains, replace the laser scanner.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.