Description: Developing motor abnormal rotation or start-up.
- Magenta developer motor rotation error
Remedy: 1. Reconnect the connector (J514) on the developing motor and the connector (J81) on the DC controller PCA. 2. Run the developing motor drive test in the actuator drive mode to verify that the developing motor is functioning correctly. If it is not functioning correctly, replace the developing motor unit.
Description: Developing motor abnormal rotation or start-up.
- Yellow developer motor rotation error
Remedy: 1. Reconnect the connector (J514) on the developing motor and the connector (J81) on the DC controller PCA. 2. Run the developing motor drive test in the actuator drive mode to verify that the developing motor is functioning correctly. If it is not functioning correctly, replace the developing motor unit.
Description: ITB motor start error or rotation error.
- ITB motor start error
Remedy: 1. Reconnect the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA. 2. Run the ITB motor drive test in the actuator drive mode to verify that the ITB motor is functioning correctly. If it is not functioning correctly, replace the ITB motor unit.
Description: ITB motor start error or rotation error.
- ITB motor rotation error
Remedy: 1. Reconnect the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA. 2. Run the ITB motor drive test in the actuator drive mode to verify that the ITB motor is functioning correctly. If it is not functioning correctly, replace the ITB motor unit.
Remedy: 1. Reconnect the connector (J518) on the developing disengagement motor, the connector (J1005) on the driver PCA and the connector (J91) on the DC controller PCA. 2. Run the sensor test in the sensor monitor mode to verify that the developing disengagement sensor is functioning correctly. If it is not, replace the developing disengagement sensor unit. 3. Run the developing unit engagement and disengagement drive test in the actuator drive mode to verify that the disengagement mechanism is functioning correctly. If it is not functioning correctly, replace the developing disengagement motor.
Remedy: 1. Check if the ITB unit is installed. 2. Reconnect the connector (J181) on the DC controller PCA. 3. Run the switch test in the sensor monitor mode to verify that the primary transfer roller disengagement switch is functioning correctly. If it is not functioning correctly, replace the primary transfer roller disengagement switch unit. 4. Run the primary transfer roller engagement and disengagement drive test in the actuator drive mode to verify that the primary transfer roller disengagement mechanism is functioning correctly. If it is not functioning correctly, replace the fuser drive unit
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.