Description: Fan Test Failed -Current not detected in one or bothfans. Error data (XX):
1 -Electronics Module fan not running. 2 -Service station fan not running. 3 -Bothfans not running. 10 -Electronics Module fan is short-circuited. 20 -Service Station fan is short-circuited. 30 -Bothfans are short-circuited. 12 -Service Station fan is not running and the Electronics Module fan is short-circuited. 21 -Electronics Module fan is not running and the Service Station fan is short-circuited.
Code: 010033
Description: The DC Motor Driver ASIC Test Failed.
Code: 010034
Description: One of the DC Motors has failed. Error data: 00010000 -Y-axis Motor Failed. 00020000 -X-axis Motor Failed. 00030000 -Both DC Motors Failed.
Code: 010035
Description: One of the Stepper Motors has failed. Error data (oXABCDEF): If the value of each letter is o, then the component is OK. If the value of each letter is different from 0 then the component has failed. X -Electronics signal failed (ignore other values). A -Elevator Stepper Motor Failed. B -Refill Stepper Motor Failed. C -Primer Stepper Motor Failed. D -Service station (Z-axis) Stepper Motor Failed. E -Service station (X-axis) Stepper Motor Failed. F -Bail Stepper Motor Failed.
Code: 010036
Description: ADC Test Failure in the Main PCA A short circuit in the Y/X-axis or ANY stepper motor. This short circuit is causing some of the fuses in the Electronics Module to burn. Error data: 00000800 -Problem with the Y-axis. 00001000 -Problem with the X-axis.
Code: 010037
Description: ADC Test Failure in the Carriage PCA.
Code: 010038
Description: A Printhead voltage could not be set -Main PCA Failure.
Code: 010039
Description: A Printhead voltage could not be set -Carriage PCA Failure