Description: Curing power regulator V null and no fault
Causes: Curing power regulator V null and no fault.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Replace the control cables to the sine-wave converter.
Code: 14.72:01
Description: Curing power regulator V null and fault
Causes: Curing power regulator V null and fault.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check the Resident Current Circuit Breakers. 4. Check the input voltage.
Code: 14.73:01
Description: Curing power regulator V lower than 140
Causes: Curing power regulator V lower than 140.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
Code: 14.74:01
Description: Curing power regulator V lower than 180
Causes: Curing power regulator V lower than 180.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
Code: 14.75:01
Description: Curing power regulator V higher than Vmax
Causes: Curing power regulator V higher than Vmax.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check the input voltage. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
Code: 14.76:11
Description: Curing power regulator V could not be read
Causes: Curing power regulator V could not be read.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Check cable connections. 3. Replace the control cables to the sine-wave converter.
Code: 14.80:10
Description: Curing power regulator current not null
Causes: Curing power regulator current not null.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Replace the sine-wave converter. 3. Run the Monitoring Sine-waves and Resistances diagnostic test.
Code: 14.81:10
Description: Curing power regulator current too high
Causes: Curing power regulator current too high.
Remedy: 1. Switch the power off at the rear of the printer, wait briefly, then switch it back on again. 2. Run the Monitoring Sine-waves and Resistances diagnostic test. 3. Check heaters with tester and replace heaters if necessary (short-circuit). 4. Replace the sine-wave converter.