Display: 41.03.YZ Unexpected size in envelope feeder To use another tray, touch "Options"
Description: The product detected a different paper size than expected. -Y = 0 Size mismatch. Detected media is longer or shorter than expected. -Y = A Size mismatch. Detected media too long. -Y = B Size mismatch. Detected media too short. -Y = C Size mismatch. Inter-page gap error. -Z = D Source is duplexer -Z = E Source is envelope feeder -Z = 2 Source is Tray 2 -Z = 3 Source is Tray 3 -Z = 4 Source is Tray 4 -Z = 5 Source is Tray 5
Remedy: Make sure that the feeder is loaded with the correct paper size and that the sliding paper guides are correctly adjusted. Use the Tray/Bin manual sensor test to verify that the envelope feeder paper sensor (PS1802) is correctly functioning. If the error persists, replace the envelope feeder.
Description: The product detected a different paper size than expected. -Y = 0 Size mismatch. Detected media is longer or shorter than expected. -Y = A Size mismatch. Detected media too long. -Y = B Size mismatch. Detected media too short. -Y = C Size mismatch. Inter-page gap error. -Z = D Source is duplexer -Z = E Source is envelope feeder -Z = 1 Source is Tray 1 -Z = 2 Source is Tray 2 -Z = 3 Source is Tray 3 -Z = 4 Source is Tray 4 -Z = 5 Source is Tray 5
Remedy: Make sure that the tray is loaded with the correct paper size and that the sliding paper guides are correctly adjusted. Use the Tray/Bin manual sensor test to verify that the cassette media switch is correctly functioning. If the error persists, replace the lifter assembly.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.