Description: The indicated tray has not lifted into the paper feed position.
Media input Tray 5 lift-up motor (M82) failure or media input Tray 6 lift-up motor (M92) failure NOTE: The Tray 5 and Tray 6 motors, sensors, and connectors numbers depend on the input device configuration.
Remedy: 1. Use the Tray 5 paper surface sensor (SR82) or Tray 6 paper surface sensor (SR92) test in the Tray/Bin manual sensor test to verify that the sensor is properly functioning. If it is not, replace the lifter drive assembly. 2. Open and close Tray 5 or Tray 6 and listen at the back of the product for the sound of the lifter motor (M82 or M92) operating. If it does not operate, replace the lifter drive assembly. 3. If the product has been serviced, check the connector (J2003) on the paper feeder controller PCA, the intermediate connector (J702), and the connector (J2006) on the paper feeder controller PCA. TIP: Check the connector (J2006) on the paper feeder controller PCA associated with the tray. 4. If the error persists, replace the cassette tray.
Description: The indicated tray has not lifted into the paper feed position.
Media input Tray 5 lift-up motor (M82) failure or media input Tray 6 lift-up motor (M92) failure NOTE: The Tray 5 and Tray 6 motors, sensors, and connectors numbers depend on the input device configuration.
Remedy: 1. Use the Tray 5 paper surface sensor (SR82) or Tray 6 paper surface sensor (SR92) test in the Tray/Bin manual sensor test to verify that the sensor is properly functioning. If it is not, replace the lifter drive assembly. 2. Open and close Tray 5 or Tray 6 and listen at the back of the product for the sound of the lifter motor (M82 or M92) operating. If it does not operate, replace the lifter drive assembly. 3. If the product has been serviced, check the connector (J2003) on the paper feeder controller PCA, the intermediate connector (J702), and the connector (J2006) on the paper feeder controller PCA. TIP: Check the connector (J2006) on the paper feeder controller PCA associated with the tray. 4. If the error persists, replace the cassette tray.
Description: The indicated tray has not lifted into the paper feed position.
Lifter motor failure (M4, M5)
Remedy: 1. Turn the product off and then on. 2. Check the connector (J51) on the DC controller PCA. 3. Check the connectors on the lifter motors. 4. Use the tray surface sensor test in the Manual sensor tests menu to verify that the sensor is properly functioning. If it is not, replace the lifter drive assembly. 5. If the error persists, replace the lifter drive assembly.
Display: 60.10.0Y Media input source <Y> pickup mechanism malfunction
Description: 60.10.01 Media input source 1 pickup mechanism malfunction • 60.10.02 Media input source 2 pickup mechanism malfunction • 60.10.03 Media input source 3 pickup mechanism malfunction • 60.10.04 Media input source 4 pickup mechanism malfunction • 60.10.05 Media input source 5 pickup mechanism malfunction • 60.10.06 Media input source 6 pickup mechanism malfunction
Remedy: 1. Turn the product off, and then on again. 2. Use the paper pick-up motor (M1, M4, M5, M92, M3301, M3304) test in the Component test to verify that the pickup motor is properly functioning. If the pickup motor is not functioning, replace the paper pick-up assembly. NOTE: Trays 4-6 motor numbers depend on the input device configuration.
Display: 66.80.02 Output accessory failure To continue turn off then on
Description: Jogger motor malfunction. Home position could not be found.
Remedy: 1. Turn the power off. 2. Make sure that the external paper handling accessory is clear of all packing materials and other obstructions. 3. Turn the power on. 4. If the error persists, replace the stapler/stacker alignment assembly.
Display: 66.80.03 Output accessory failure To continue turn off then on
Description: Staple motor malfunction. Stapler could not return to home position.
Remedy: 1. Turn the power off. 2. Make sure that the external paper handling accessory is clear of all packing materials and other obstructions. 3. Turn the power on. 4. If the error persists, replace the stapler assembly.
Display: 66.80.19 Output accessory failure To continue turn off then on
Description: Self-priming malfunction. Not able to complete self-priming after 11 attempts.
Remedy: 1. Turn the power off. 2. Make sure that the external paper handling accessory is clear of all packing materials and other obstructions. 3. Turn the power on. 4. If the error persists, replace the stapler assembly.
Nhận ưu đãi sớm nhất khi chương trình diễn ra
Đăng ký nhận bản tin
Việc cho phép sử dụng cookie sẽ giúp cải thiện trải nghiệm của bạn trên trang web này.
Chính sách cookie
Những cookie này là cần thiết để trang web hoạt động đúng cách.
Những cookie này giúp chúng tôi hiểu cách khách truy cập tương tác với trang web.
Những cookie này được sử dụng để cung cấp quảng cáo cá nhân hóa.