Code: 99.00.05

Display: 99.00.05 Upgrade not performed timeout during receive
Description: A remote firmware upgrade (RFU) was not performed. I/O time-out when reading image data.
Remedy: The most common cause is an issue with the network environment. Make sure that there is a good connection to the device and attempt the upgrade again, or upgrade using the easy-access USB port.

Code: 99.00.06

Display: 99.00.06 Upgrade not performed error reading upgrade
Description: A remote firmware upgrade (RFU) was not performed. Unexpected read error when reading header number and size.
Remedy: 1. Download the RFU file and attempt the upgrade again. 2. If the error persists, replace the hard disk.

Code: 99.00.07

Display: 99.00.07 Upgrade not performed error reading upgrade
Description: A remote firmware upgrade (RFU) was not performed. Unexpected read error when reading rest of header.
Remedy: 1. Download the RFU file and attempt the upgrade again. 2. If the error persists, replace the hard disk.

Code: 99.00.08

Display: 99.00.08 Upgrade not performed error reading upgrade
Description: Description A remote firmware upgrade (RFU) was not performed. Unexpected read error when reading image data.
Remedy: 1. Download the RFU file and attempt the upgrade again. 2. If the error persists, replace the hard disk.

Code: 99.00.09

Display: 99.00.09 Upgrade canceled by user
Description: A remote firmware upgrade (RFU) was not performed. The RFU was canceled by the user.
Remedy: Re-send the RFU.

Code: 99.00.10

Display: 99.00.10 Upgrade canceled by user
Description: A remote firmware upgrade (RFU) was not performed. Job canceled when reading header number and size.
Remedy: Re-send the RFU.

Code: 99.00.11

Display: 99.00.11 Upgrade canceled by user
Description: A remote firmware upgrade (RFU) was not performed. Job canceled when reading rest of header.
Remedy: Re-send the RFU.

Code: 99.00.12

Display: 99.00.12 Upgrade not performed the file is invalid
Description: A remote firmware upgrade (RFU) was not performed. Header number is 1 but header size doesn’t match version 1 size.
Remedy: Download the RFU file again. Make sure that you download the file for the correct product model. Resend the RFU.