Các lỗi thường gặp

Code :
  • Code: 59.00.F0
  • Display: 59.00.YY Error To continue turn off then on
  • Description: Printing error
    T1 alienation mechanism failure
  • Remedy: 1. Make sure that the ITB is correctly installed. 2. Use the T1 roller alienation switch (SW5) test in the Manual sensor test to verify that the switch is properly functioning. If it is not, replace the main drive assembly. 3. Use the T1 roller engagement and disengagement drive test in the component test to verify that the T1 roller disengagement mechanism is properly functioning. If it is not, replace the fuser drive assembly. 4. If the product has been serviced, check the connector (J181) on the DC controller PCA.
  • Code: 59.05.50
  • Display: 59.0X.50 Error To continue turn off then on
  • Description: Motor startup error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
    Black image drum start up error (ITB motor; M1)
  • Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
  • Code: 59.05.70
  • Display: 59.0X.70 Error To continue turn off then on
  • Description: Motor abnormal rotation
    Black developer motor abnormal start up error (ITB motor; M1)
  • Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
  • Code: 59.05.80
  • Display: 59.0X.80 Error To continue turn off then on
  • Description: Developer motor failure
    Black developer motor failure error (ITB motor; M1)
  • Remedy: 1. Use the ITB drum motor (M1) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the ITB motor assembly. 2. If the product has been serviced, check the connector (J517) on the ITB motor and the connector (J81) on the DC controller PCA.
  • Code: 59.06.50
  • Display: 59.0X.50 Error To continue turn off then on
  • Description: Motor startup error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
    CMY drum motor (M2) start up error
  • Remedy: 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
  • Code: 59.06.60
  • Display: 59.0X.60 Error To continue turn off then on
  • Description: Motor rotational error X= 5 black, X = 6 cyan, X = 7 magenta, X = 8 yellow
  • Remedy: CMY drum motor (M2) rotation error 1. Use the drum motor (M2) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the drum motor assembly. 2. If the product has been serviced, check the connector (J515) on the drum motor and the connector (J81) on the DC controller PCA.
  • Code: 59.06.70
  • Display: 59.0X.70 Error To continue turn off then on
  • Description: Motor abnormal rotation
    CMY developer motor (M3) abnormal start up error
  • Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.
  • Code: 59.06.80
  • Display: 59.0X.80 Error To continue turn off then on
  • Description: Developer motor failure
    CMY developer motor (M3) failure error
  • Remedy: 1. Use the developer motor (M3) drive test in the Component test to verify that the motor is properly functioning. If it is not, replace the developer motor assembly. 2. If the product has been serviced, check the connector (J514) on the developer motor and the connector (J81) on the DC controller PCA.