Display: 50.<X> Fuser To continue turn off then on
Description: A fuser error has occurred.
high fuser temperature
Remedy: - Turn the product off, and then on. - Reseat the connection to the fuser and the DC controller. - Replace the fuser. - Replace the upper cable guide assembly. - Replace the low voltage power supply. - Replace the DC controller
Display: 50.<X> Fuser To continue turn off then on
Description: A fuser error has occurred.f
aulty fuser.
Remedy: - Turn the product off, and then on. - Reseat the connection to the fuser and the DC controller. - Replace the fuser. - Replace the upper cable guide assembly. - Replace the low voltage power supply. - Replace the DC controller
Display: 50.<X> Fuser To continue turn off then on
Description: A fuser error has occurred.
inconsistent fuser.
Remedy: - Turn the product off, and then on. - Reseat the connection to the fuser and the DC controller. - Replace the fuser. - Replace the upper cable guide assembly. - Replace the low voltage power supply. - Replace the DC controller
Display: 50.<X> Fuser To continue turn off then on
Description: A fuser error has occurred.
faulty fuser.
Remedy: - Turn the product off, and then on. - Reseat the connection to the fuser and the DC controller. - Replace the fuser. - Replace the upper cable guide assembly. - Replace the low voltage power supply. - Replace the DC controller
Description: A fuser error has occurred.
a beam detect error.
Remedy: - Turn off the product, and turn it on. - Reseat the connections to the DC controller and the laser scanner. - Replace the laser/scanner. - Replace the upper cable guide assembly. - Replace the DC controller.
Display: 52.<XY> Error To continue turn off then on
Description: A product error occurred.
a laser/scanner error. a laser/scanner rotation error.
Remedy: - Turn the product off and turn it on. - Reseat the connection to the DC controller and the laser scanner. - Replace the laser/scanner. - Replace the DC controller.